Gestetner B147 Service Manual page 838

Table of Contents

Advertisement

BIT SWITCHES
FAX Switch 0D
No
FUNCTION
0-6
Not used
7
Scan width for A5 lengthwise or
B5 lengthwise originals
0: 210 mm (8.5")
1: Original width
FAX Switch 0E
No
0
Not used
1
Scan resolution unit
0: mm
1: inches
2-7
Not used
FAX Switch 0F
No
0
A4/LT LEF-to-SEF turn
1
Not used
2
A5/HLT SEF-to-LEF turn
3-7
Not used
FAX Switch 10 ~ 1F - Not used (do not change the settings)
B603
Do not change the settings.
0: The machine scans the original as 210 mm (8.5")
width. The transmitted image has a blank area on
the right.
1: The machine scans 148 mm (A5) or 182 mm (B5)
and centers the scanned data on a 216 mm width
transmitted image.
FUNCTION
FUNCTION
COMMENTS
COMMENTS
Do not change the settings.
This bit determines which resolution unit will be
used for scanning a fax message.
Default setting: mm
Do not change the settings.
COMMENTS
0: OFF/1: ON
Bit 0 activates or deactivates the A4/LT LEF-to-
SEF turn function. When this function is
activated, the machine sends A4/LT SEF data
even when the machine has fed an A4/LT LEF
original.
Do not change the setting.
0: OFF/1: ON
Bit 2 activates or deactivates the A5/HLT SEF-
to-LEF turn function. When this function is
activated, the machine sends A5/HLT LEF data
even when the machine has fed an A5/HLT
SEF original.
Do not change the settings.
44
SP No. 3-201-014
SP No. 3-201-015
SP No. 3-201-015
SP No. 3-201-016
SM