Gestetner B147 Service Manual page 332

Table of Contents

Advertisement

COPY SERVICE MODE
5-501
PM Alarm
5501-1
PM Alarm Level
5501-2
Original Count Alarm
5-504
Jam Alarm
5504-1
Sets the alarm to sound for the specified jam level (document misfeeds are not
included).
[0~3 / 3 / 1 step]
0: Zero (Off)
1: Low (2.5K jams)
2: Medium (3K jams)
3: High (6K jams)
5-505
Error Alarm
5-507
Supply Alarm
5-507-1
Paper Supply Alarm
5-507-2
Staple Supply Alarm
5-507-3
Toner Supply Alarm
5-507-128
Interval :Others
5-507-132
Interval :A3
5-507-133
Interval :A4
5-507-134
Interval :A5
5-507-141
Interval :B4
5-507-142
Interval :B5
5-507-160
Interval :DLT
5-507-164
Interval :LG
5-507-166
Interval :LT
5-507-172
Interval :HLT
5-508*
CC Call
5-508-1*
Jam Remains
Enables/disables initiating a call for an unattended paper jam.
5-508-2*
Continuous Jams
Enables/disables initiating a call for consecutive paper jams.
5-508-3*
Continuous Door Open
Enables/disables initiating a call when the front door remains open.
5-508-4*
Low Call Mode
Enables/disables the new call specifications designed to reduce the number of
calls.
5-508-11*
Jam Detection: Time Length
Sets the time a jam must remain before it becomes an "unattended paper jam". This
setting is enabled only when SP5508 004 is set to 1.
B147/B149/B190
*CTL
[0~9999 / 0 / 1 step]
0: Alarm off
1~9999: Alarm goes off when Value (1~9999)
counter
0: No alarm sounds
1: Alarm sounds after the number of originals passing
through the ARDF ≥ 10,000
*CTL
*CTL
[0~255 / 50 / 100 copies per step] Japan only
*CTL
0: Off, 1: On, DFU
0: Off, 1: On, Japan only
0: Off, 1: On, DFU
[00250 ~ 10000 / 1000 / 1 Step] DFU
*CTL
0: Disable, 1: Enable
0: Disable, 1: Enable
0: Disable, 1: Enable
0: Normal mode, 1: Reduced mode
[03~30 / 10 / 1]
5-44
PM
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B149B190

Table of Contents