SCANNER SP MODE
2-008
[Full Color (Photo) mode settings]
2-008-1
MTF Filter Coefficient
(Main scan)
Selects the MTF filter coefficient in the main scan direction when using grayscale
processing mode.
Select a higher number for a stronger filter.
If this is "0", the MTF filter is not applied
2-008-2
MTF Filter Coefficient
(Sub scan)
As above, for sub scan
2-008-3
Smoothing Filter
Selects the smoothing pattern when using grayscale processing mode.
A larger value could cause moiré to appear in the image.
Adjusts the scanner gamma for RGB.
2-008-4
R-Gamma Curve
2-008-5
G-Gamma Curve
2-008-6
B-Gamma Curve
Adjusts the image density for each image density level for Text mode when using
binary picture processing mode.
2-008-11
Notch No.7 (Lighter): R - Brightness
2-008-12
Notch No.7 (Lighter): G - Brightness
2-008-13
Notch No.7 (Lighter): B - Brightness
2-008-14
Notch No.7 (Lighter): R - Contrast
2-008-15
Notch No.7 (Lighter): G - Contrast
2-008-16
Notch No.7 (Lighter): B - Contrast
2-008-17
Notch No.7 (Lighter): R - Threshold
2-008-18
Notch No.7 (Lighter): G - Threshold
2-008-19
Notch No.7 (Lighter): B - Threshold
2-008-20
Notch No.6: R - Brightness
2-008-21
Notch No.6: G - Brightness
2-008-22
Notch No.6: B - Brightness
2-008-23
Notch No.6: R - Contrast
2-008-24
Notch No.6 G - Contrast
2-008-25
Notch No.6: B - Contrast
2-008-26
Notch No.6: R - Threshold
2-008-27
Notch No.6: G - Threshold
2-008-28
Notch No.6: B - Threshold
2-008-29
Notch No.5: R - Brightness
2-008-30
Notch No.5: G - Brightness
2-008-31
Notch No.5: B - Brightness
2-008-32
Notch No.5: R - Contrast
2-008-33
Notch No.5 G - Contrast
2-008-34
Notch No.5: B - Contrast
2-008-35
Notch No.5: R - Threshold
2-008-36
Notch No.5: G - Threshold
2-008-37
Notch No.5: B - Threshold
2-008-38
Notch No.4 (Middle): R - Brightness
B147/B149/B190
*
[ 0 to 255 / 5 / 1/step ] DFU
CTL
*
[ 0 to 255 / 5 / 1/step ] DFU
CTL
*
[ 0 to 255 / 0 / 1/step ] DFU
CTL
*
[ 0 to 10 / 10 / 1 /step ] DFU
CTL
*
[ 0 to 255 / 128 / 1/step ] DFU
CTL
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU
[ 0 to 255 / 128 / 1/step ] DFU