6.12.5 WASTE OIL

[I]
[H]
[F]
[G]
Bottle Set Sensor
Excess fusing oil is collected in the waste oil bottle [H] through the pipe [I]. There is
a feeler [E] behind the waste oil bottle holder [G]. The feeler is linked to the bottle
set sensor [D]. The feeler is pushed when the bottle is in the holder and the holder
is set in place.
NOTE: 1) The feeler goes through an opening [F] on the rear side of the holder.
The bottle pushes the feeler directly.
2) The bottle set sensor is checked when the main switch is turned on or
when the front or left door is opened and closed.
If the sensor does not detect the bottle, the message, "Waste Oil Bottle Setting
Error," is displayed. This message is cleared after the bottle is set and the front
cover is closed (or the main switch is turned off and on). Just opening and closing
the cover does not clear the message.
NOTE: With this error message, another message, "Waste Oil Bottle is Almost
Full," can be displayed (
SM
[D]
[E]
Waste Oil Sensor).
6-95