Gestetner B147 Service Manual page 813

Table of Contents

Advertisement

Code
Meaning
2-12
Modem clock irregularity
2-13
Modem initialization error
2-20
Abnormal coding/decoding
(cpu not ready)
2-23
JBIG compression or
reconstruction error
2-24
JBIG ASIC error
2-25
JBIG data reconstruction
error (BIH error)
2-26
JBIG data reconstruction
error (Float marker error)
2-27
JBIG data reconstruction
error (End marker error)
2-28
JBIG data reconstruction
error (Timeout)
2-50
The machine resets itself for
a fatal FCU system error
2-51
The machine resets itself
because of a fatal
communication error
4-01
Line current was cut
4-10
Communication failed
because of an ID Code
mismatch (Closed Network)
or Tel. No./CSI mismatch
(Protection against Wrong
Connections)
5-00
Data construction not
possible
5-01
Data reconstruction not
possible
5-10
DCR timer expired
5-20
Storage impossible because
of a lack of memory
5-21
Memory overflow
5-22
Mode table overflow after
the second page of a
scanned document
SM
Suggested Cause/Action
• Replace the FCU.
• Turn off the machine, then turn it back on.
• Update the modem ROM.
• Replace the FCU.
• Replace the FCU.
• Turn off the machine, then turn it back on.
• Replace the EXFUNC board if the error is
frequent.
• Turn off the machine, then turn it back on.
• Replace the EXFUNC board if the error is
frequent.
• JBIG data error
• Check the sender's JBIG function.
• Update the MBU ROM.
• If this is frequent, update the ROM, or replace the
FCU.
• If this is frequent, update the ROM, or replace the
FCU.
• Check the line connector.
• Check the connection between FCU and NCU.
• Check for line problems.
• Replace the FCU or the NCU.
• Get the ID Codes the same and/or the CSIs
programmed correctly, then resend.
• The machine at the other end may be defective.
• Replace the FCU.
• Temporary memory shortage.
• Test the SAF memory.
• Replace the FCU or optional EXMEM board
• Wait for the messages which are currently in the
memory to be sent or delete some files from
memory.
19
ERROR CODES
B603

Advertisement

Table of Contents
loading

This manual is also suitable for:

B149B190

Table of Contents