5801 1
Memory Clear - All Clear
Resets all data for process control and all software counters, and restores all
modes and adjustments to their default values. To execute, hold down  for
over 3 seconds, and then turn the copier off and on again.
Use this SP only after replacing the NVRAM, or after the copier has
malfunctioned due to a damaged NVRAM.
5801 014
Clear DCS Settings
Initializes SP setting related to DCS. DCS (Delivery Control Service) manages
the Scan Router connection. To execute, hold down  for over 3 seconds,
and then turn the copier off and on again.
5824
NVRAM Data Upload
Uploads the UP and SP mode data (except for counters and the serial
number) from NVRAM on the control board to a flash memory card.
While using this SP mode, always keep the front cover open. This prevents a
software module accessing the NVRAM during the upload.
5825
NVRAM Data Download
Downloads the content of a flash memory card to the NVRAM on the control
board.
5832
HDD Formatting
Enter the SP number for the partition to initialize, then press #. When
execution ends, cycle the machine off and on.
5832 1
ALL
5832 2
IMH
5836*
Capture Setting s
5836 1*
Capture Function (0:Off 1:On)
0: With this function disabled, the settings related to the capture feature
cannot be initialized, displayed, or selected.
1: With this function enabled, the settings screen for the capture features an
be displayed.
B692/B694
Initializes entire content of the HDD.
Initializes 1) documents stored on the document
server, 2) stamp print data, 3) scanner delivery images,
4) fax delivery images.
0: Disable, 1: Enable