SC TABLE
SC No.
Item
SC 998
Application start
No applications start within 60
error
seconds after the power is
turned on.
B147/B149/B190
Definition
Possible Cause
• Loose connection of
RAM-DIMM, ROM-
DIMM
• Defective controller
• Software problem
Related
Troubleshooting Procedure
SCs
1. Turn the main switch off and on.
2. Check if the RAM-DIMM and ROM-
DIMM are properly connected.
3. Reinstall the controller system
firmware.
4. Replace the controller.
4-52
Type
CTL