7-803-33 S: Toner [C]
Displays the total operating time for the toner attraction pump.
7-803-34 Toner Supply[K]
7-803-35 Toner Supply[Y]
7-803-36 Toner Supply[M]
7-803-37 Toner Supply[C]
Displays the value given by the following formula:
(Current revolution ÷ Target revolution) × 100, where "Current revolution" is the
current value for the counter of the part, and "Target revolution" is the values of SP7-
803-17 through 27. This shows how much of the unit's expected lifetime has been
used up.
The R% counter is based on rotations, not prints. If the number of rotations reaches
the limit, the machine enters the end condition for that unit. If the print count lifetime is
reached first, the machine also enters the end condition, even though the R% counter
is still less than 100%.
Oil supply unit: When the R% counter reaches 100%, it enters the near-end condition,
not the end condition. The end condition occurs some number of rotations after this
(not adjustable).
NOTE: The machine internally adjusts or compensates as necessary, depending on
7-803-38 R(%): PCU [K]
7-803-39 R(%): PCU [Y]
7-803-40 R(%): PCU [M]
7-803-41 R(%): PCU [C]
7-803-42 R(%): Dev [K]
7-803-43 R(%): Dev [Y]
7-803-44 R(%): Dev [M]
7-803-45 R(%): Dev [C]
7-803-46 R(%): Oil Spply
7-803-47 R(%): Fusing
7-803-48 S: Trans Cln
7-803-49 R: Trans Cln
7-804
[PM Counter Reset] PM Counter Clear
(Unit, [Color])
Dev.: Development Unit, PF: Paper Feed Rollers, Transfer: Transfer Unit
Clears the PM counter.
Press the Enter key after the machine asks "Execute?," which will store the PM
counter value in SP7-906-1 to 25 (PM Counter – Previous), and reset the value
of the current PM counter to 0.
NOTE: The LCT is counted as the 3rd feed station.
7-804-1 Paper
7-804-2 PCU [K]
7-804-3 PCU [Y]
7-804-4 PCU [M]
7-804-5 PCU [C]
7-804-6 Dev. [K]
7-804-7 Dev. [Y]
7-804-8 Dev. [M]
7-804-9 Dev. [C]
7-804-10 Oil Supply
7-804-11 PF By-pass
7-804-12 PF Tray 1
SM
*BCU
conditions of machine usage. Due to this, at the oil supply unit near-end
condition, the R% counter of the oil supply unit can be 100%, lower than
100%, or higher than 100%.
*BCU
COPY SERVICE MODE
[ 0 to 9999999 / - / 1 s/step ]