19. Plug in the machine and turn the main power switch on. The machine
automatically starts the initialization procedure. After this has finished, the Start
button LED (
20. Make copies of image samples (text, photo, and text/photo modes).
21. Perform the Automatic Color Calibration (ACC) as follows:
1) Print the ACC test pattern (UP mode > Maintenance > ACC > Start).
2) Place the printout on the exposure glass.
3) Place 10 sheets of white paper on top of the test chart.
4) Close the ARDF or the platen cover.
5) Press "Start Scanning" on the LCD panel. The machine starts the ACC.
22. Check that the sample image has been copied normally.
23. Check that the circuit breaker works normally.
Settings Relevant to Contract
If the customer has a service contract, change the settings of the following SPs in
accordance with it.
NOTE: You must select one of the counter methods (developments/prints) in
accordance with the contract (
Item
Counting
SP5-045-001
method
A3/11" x 17"
SP5-104-001
double
counting
Serivice Tel.
SP5-812-001
No. Setting
through 004
SM
) turns green.
SP No.
Specifies whether the counting method
used in meter charge mode is based on
developments or prints.
NOTE: You can specify this setting only
one time. After you have specified
it, you cannot change the setting.
Specifies whether the counter is doubled
for A3/11" x 17" paper.
Programs the service station fax number.
The number is printed on the counter list
when the meter charge mode is selected,
so that the user can fax the counter data to
the service station.
MACHINE INSTALLATION
SP5-045-001).
Function
1-11
Default
"0":
Developments
"No": Single
counting
B147/B149/B190