Gestetner B147 Service Manual page 320

Table of Contents

Advertisement

COPY SERVICE MODE
3-906
[PC Self Check] Process Control Self-checks
3-906-5
K Coefficient
Sets the coefficient to calculate the counter value for black-and-white prints.
With the default setting (100), counters used for process control count up by 1 when 1
black-and-white print has been made.
3-910
[Vmin Display] Vmin Display ([Color])
3-910-1
[K]
Displays the current Vmin value for K
3-910-2
[Color]
Displays the lowest current Vmin value for the colors (CMY).
3-911
[Vt Current Display] Vt Current Display ([Color])
Displays the current Vt value.
3-911-1 [K]
3-911-2 [Y]
3-911-3 [M]
3-911-4 [C]
3-912
[Vt Average Display] Vt Average Display ([Color])
Displays the average Vt value.
3-912-1 [K]
3-912-2 [Y]
3-912-3 [M]
3-912-4 [C]
3-913
[Tonver Supply Time] Toner Supply Time Display ([Color])
Displays the toner supply clutch on time for the most recent page.
3-913-1 [K]
3-913-2 [Y]
3-913-3 [M]
3-913-4 [C]
B147/B149/B190
*BCU
[ 0 to 1.00 / 1.00 / 0.01/step ] DFU
*BCU
[ 0 to 2.00 / 0 / 0.01/step ]
*BCU
[ 0 to 2.00 / 0 / 0.01/step ]
*BCU
[ 0.0 to 5.0 / - / 0.1V/step ]
*BCU
*BCU
*BCU
*BCU
[ 0.0 to 5.0 / - / 0.1V/step ]
*BCU
*BCU
*BCU
*BCU
[ 0 to 5000 / - / 10 ms/step ]
*BCU
*BCU
*BCU
5-32
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B149B190

Table of Contents