17004660F1/F3
17005660F1
17406368F1
17406368F3
17806368F1
17806368F3
17406369F1
17406369F3
617004660F1-34A
November 2014
NetVanta 4660/5660
Hardware Installation Guide
NetVanta 4660 Chassis
NetVanta 5660 Chassis
NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A
NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex B
NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex A
NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex B
NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex A
NetVanta Carrier Ethernet Quad VDSL2 EFM Module, Annex B

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN NetVanta 4660

  • Page 1 NetVanta 4660/5660 Hardware Installation Guide 17004660F1/F3 NetVanta 4660 Chassis 17005660F1 NetVanta 5660 Chassis 17406368F1 NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex A 17406368F3 NetVanta Carrier Ethernet Quad SHDSL EFM Module, Annex B 17806368F1 NetVanta Carrier Ethernet Octal SHDSL EFM Module, Annex A...
  • Page 2 To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
  • Page 3 NetVanta 4660/5660 Series Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 4 These units contain no user-serviceable parts. They should only be serviced by qualified service personnel. Additional safety guidelines, such as Waste Electrical and Electronic Equipment (WEEE), are given in the document NetVanta Safety and Regulatory Information available online at http://supportforums.adtran.com. Save These Important Safety Instructions Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 5 Advance notification and the opportunity to maintain uninterrupted service are given. 4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected, or it is certain the equipment is not malfunctioning.
  • Page 6 Department of Communications. Cet appareil numérique respecte les limites de bruits radioelectriques applicables aux appareils numériques de Class A prescrites dans la norme sur le materiel brouilleur: “Appareils Numériques,” NMB-003 edictee par le ministre des Communications. Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 7 General Public License (GPL). For a list of third-party software and their licenses, go to http://www.adtran.com/software/EULA. You can obtain the complete corresponding source code of such software components from ADTRAN for a period of three years after our last shipment of this product by sending a money order or check for $5 to: ADTRAN, Inc, P.O.
  • Page 8 Service and Warranty NetVanta 4660/5660 Series Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 9: Table Of Contents

    NetVanta 4660/5660 Series Front Panel Design ........
  • Page 10 Table of Contents NetVanta 4660/5660 Series Copyright © 2013 ADTRAN, Inc. 617004660F1-34A...
  • Page 11 NetVanta 4660/5660 Series Front Panel Layout ........
  • Page 12 List of Figures NetVanta 4660/5660 Series Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 13 Table A-8. Quad VDSL2 Pinouts ............38 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 14 List of Tables NetVanta 4660/5660 Series Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 15: Introduction

    Supplying Power to the Unit on page 33 • Installing Network Modules on page 33 For information on NetVanta 4660/5660 Series configuration for a specific application, refer to the configuration guides provided on the ADTRAN Support Community. For details on the command line interface (CLI), refer to AOS Command Reference Guide.
  • Page 16: Physical Description

    (EoX, VDSL2, GPON, PPP over Ethernet (PPPoE)). The NetVanta 5660 builds on the architecture of the NetVanta 4660 and is designed to allow service providers to provide Gigabit throughput for both Layer 2 and Layer 3 services. Service providers can deliver higher bandwidth services to their customers for mobile devices as well as reliable and fast connectivity for cloud-based applications.
  • Page 17: Netvanta 4660/5660 Series Front Panel Design

    Set of 4 rubber mounting feet • Six mounting screws • Quick start guide NetVanta 4660/5660 Series Front Panel Design The NetVanta 4660/5660 Series front panel is shown below along with a description of all connectors and interfaces. NetVanta 4660 STAT 1 PPS GIG 0/1...
  • Page 18: Led Descriptions

    Option Slot The option slot accepts a variety of network modules (refer to Option Modules on page 23). LED Descriptions The following table describes LED activity for the NetVanta 4660/5660 Series. Table 1. Front Panel Status LED Behaviors Color Indication STAT Unit is not receiving power.
  • Page 19: Features And Specifications

    Universal edge device supporting modular Layer 2/3 Carrier Ethernet services with Gigabit combo interfaces NetVanta 5660 • Same functionality as the NetVanta 4660 with the addition of Gigabit line rate for both Layer 2 and Layer 3 routing Physical Interfaces Ethernet •...
  • Page 20: Security

    • RADIUS AAA • SSH CLI and SSL GUI Content Filtering • Inherent URL filter • Top website reports • Integration with Websense® Virtual Private Network (VPN) (Optional) • IPSec Tunnel Mode: Tunnels 1,000 Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 21: Dsl Features

    Fault and Performance Management • IEEE 802.3ah EFM standard • ITU-T Y.1731 CFM, PM • IEEE 802.3ah Link OAM • ITU-T Y.1731 CFM, PM • Supports OAM management status and loopback messaging • Network monitoring enhancements 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 22: Environment

    FCC Part 15, Class B • UL 60950-1, Second Edition • EN 60950, Second Edition, A1, A11, A12 • AS/NZS 60950.1 • CSA C22.2 No. 60950-1, Second Edition • CE Mark • ETSI 300 • RoHS Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 23: Option Modules

    Option Modules OPTION MODULES The NetVanta 4660/5660 Series supports several option modules designed to meet a variety of networking requirements. The option modules include plug-in network modules. Network modules are cards that plug directly into the option module slot located on the front of the base unit.
  • Page 24: Network Modules

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 25: Figure 3. Netvanta Carrier Ethernet Quad Shdsl Efm Module, Annex B

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 26: Figure 4. Netvanta Octal Shdsl Efm Network Module, Annex A

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 27: Figure 5. Netvanta Carrier Ethernet Octal Shdsl Efm Module, Annex B

    SHDSL loop is trained and EFM group is established. Amber (flashing) SHDSL loop is trained but EFM group is not established. Amber (solid) SHDSL loop is in test. Red (flashing) SHDSL loop is in handshake process. Red (solid) SHDSL loop connection failure. 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 28: Figure 6. Netvanta Carrier Ethernet Quad Vdsl2 Efm Module, Annex A

    VDSL loop is trained and EFM group is established. Amber (flashing) VDSL loop is trained but EFM group is not established. Amber (solid) VDSL loop is in test. Red (flashing) VDSL loop is in handshake process. Red (solid) VDSL loop connection failure. Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 29: Figure 7. Netvanta Carrier Ethernet Quad Vdsl2 Efm Module, Annex B

    VDSL loop is trained and EFM group is established. Amber (flashing) VDSL loop is trained but EFM group is not established. Amber (solid) VDSL loop is in test. Red (flashing) VDSL loop is in handshake process. Red (solid) VDSL loop connection failure. 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 30: Unit Installation

    ADTRAN unit to Ethernet cables that run outside the building, ADTRAN's Ethernet Port Protection Device (EPPD) (P/N 1700502G1) must be connected between the unit and the outside plant cable. Use of any Ethernet protector other than ADTRAN's for this purpose will void the user's warranty.
  • Page 31: Mounting Options

    Have an assistant hold the unit in position as you install two mounting bolts through the unit’s brackets and into the equipment rack using a #2 Phillips-head screwdriver. Apply power to the unit (refer to Supplying Power to the Unit on page 33). 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 32: Figure 8. Wallmount Installation

    Decide on a location for the NetVanta, keeping in mind that the unit needs to be mounted at or below eye-level so that the LEDs are viewable. The NetVanta 4660/5660 Series can only be wall mounted with the front panel facing upward (see Figure 8 on page 32).
  • Page 33: Connecting Ground To The Unit

    Supplying Power to the Unit The NetVanta 4660/5660 Series connects to a 48 VDC power source. To power this unit, follow the steps below. • Use a reliably grounded 48VDC SELV source.
  • Page 34: Figure 9. Network Module Installation

    ADTRAN’s Support Forum For details on the CLI, refer to the AOS Command Reference Guide. All other related documents are also available online on ADTRAN’s Support Forum. Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 35: Appendix A. Connector Pin Definitions

    Clear to Send (output) — Unused Table A-2. SFP Slot Pinouts Name Name TGND RGND TX FAULT TX DISABLE MOD DEF(2) RGND MOD DEF(1) VccR MOD DEF(0) VccT RATE SELECT TGND RGND RGND TGND 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 36: Table A-3. 1000Base-T Gigabit Ethernet Port Pinouts

    Transmit/Receive Negative TRD1- Transmit/Receive Negative TRD3+ Transmit/Receive Positive TRD3- Transmit/Receive Negative Table A-4. T4 Port Pinouts Name Description — Unused Transmit data toward the network–Ring Transmit data toward the network–Tip — Unused Ground — Unused Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...
  • Page 37: Network Module Pinouts

    Loop 8 - Tip Loop 6 - Ring Loop 8 - Ring — Unused — Unused Loop 5 - Tip Loop 7 - Tip Loop 5 - Ring Loop 7 - Ring — Unused — Unused 617004660F1-34A Copyright © 2014 ADTRAN, Inc.
  • Page 38: Table A-8. Quad Vdsl2 Pinouts

    Appendix A NetVanta 4660/5660 Series Table A-8. Quad VDSL2 Pinouts Name Description 1, 2 — Unused Ring Ring lead of the 2-wire interface Tip lead of the 2-wire interface 5, 6 — Unused Copyright © 2014 ADTRAN, Inc. 617004660F1-34A...