DGS-3612G:4#show syslog host
Command: show syslog host
Syslog Global State: Disabled
Host Id Host IP Address
-------
1
2
3
Total Entries : 3
DGS-3612G:4#
config system_severity
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
xStack DGS-3612G Layer 3 Gigabit Ethernet Managed Switch CLI Manual
---------------
10.1.1.2
10.40.2.3
10.21.13.1
To configure severity level of an alert required for log entry or trap message.
config system_severity [trap | log | all] [critical | warning | information]
This command is used to configure the system severity levels on the Switch.
When an event occurs on the Switch, a message will be sent to the SNMP
agent (trap), the Switch's log or both. Events occurring on the Switch are
separated into three main categories, these categories are NOT precisely the
same as the parameters of the same name (see below).
Information – Events classified as information are basic events
occurring on the Switch that are not deemed as problematic, such as
enabling or disabling various functions on the Switch.
Warning - Events classified as warning are problematic events that are
not critical to the overall function of the Switch but do require attention,
such as unsuccessful downloads or uploads and failed logins.
Critical – Events classified as critical are fatal exceptions occurring on
the Switch, such as hardware failures or spoofing attacks.
Choose one of the following to identify where severity messages are to be
sent.
trap – Entering this parameter will define which events occurring on
the Switch will be sent to a SNMP agent for analysis.
log – Entering this parameter will define which events occurring on
the Switch will be sent to the Switch's log for analysis.
all – Entering this parameter will define which events occurring on
the Switch will be sent to a SNMP agent and the Switch's log for
analysis.
Choose one of the following to identify what level of severity warnings are to
be sent to the destination entered above.
critical – Entering this parameter along with the proper destination,
stated above, will instruct the Switch to send only critical events to
the Switch's log or SNMP agent.
warning – Entering this parameter along with the proper destination,
stated above, will instruct the Switch to send critical and warning
events to the Switch's log or SNMP agent.
information – Entering this parameter along with the proper
destination, stated above, will instruct the switch to send
informational, warning and critical events to the Switch's log or
SNMP agent.
Only administrator-level users can issue this command.
Severity
Facility UDP port Status
--------------
--------
All
Local0
514
All
Local0
514
All
Local0
514