show dvmrp nexthop
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To display DVMRP routing next hop table:
show dvmrp
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To show DVMRP configurations:
xStack DGS-3612G Layer 3 Gigabit Ethernet Managed Switch CLI Manual
Used to display the current DVMRP routing next hop table.
show dvmrp nexthop {ipaddress <network_address> | ipif
<ipif_name 12>}
This command will display the DVMRP routing next hop table.
<ipif_name 12> − The name of the IP interface for which to display the
current DVMRP routing next hop table.
ipaddress <network_address> − The IP address and netmask of the
destination. The address and mask information can be specified using
the traditional format (for example, 10.1.2.3/255.0.0.0 or in CIDR format,
10.1.2.3/8).
None.
DGS-3612G:4#show dvmrp nexthop
Command: show dvmrp nexthop
Source IP Address/Netmask Interface Name Type
-----------------
10.0.0.0/8
10.0.0.0/8
20.0.0.0/8
20.0.0.0/8
30.0.0.0/8
30.0.0.0/8
Total Entries: 6
DGS-3612G:4#
Used to display the current DVMRP settings on the Switch.
show dvmrp {<ipif_name 12>}
The command will display the current DVMRP routing table.
<ipif_name 12> − This parameter will allow the user to display DVMRP
settings for a specific IP interface.
None.
---------------
------
ip2
Leaf
ip3
Leaf
System
Leaf
ip3
Leaf
System
Leaf
ip2
Leaf
242

Hide quick links: