Kyocera 300ci Service Manual page 81

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

Maintenance
item No.
Setting: [Set MOTOR3]
U053
1. Select the item to be adjusted.
Display
MPF
Eject Motor
OPT Eject
Fixing Motor
Duplex Motor
Feed Motor
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
Setting: [Set MOTOR4]
1. Select the item to be adjusted.
Display
Drum K(Full) BW
*1: 50/40 ppm model *2: 40/40 ppm model *3: 25/25, 30/30 ppm model
Setting: [Set MOTOR5]
1. Select the item to be adjusted.
Display
Dev K(BW Convey)
TC Motor (F) BW
MID Roller Motor BW Middle motor (MM)
Regist Motor BW
Polygon (F) BW
Setting: [Set MOTOR6]
1. Select the item to be adjusted.
Display
MPT BW
Eject Motor BW
OPT Eject BW
Fixing Motor BW
Duplex Motor BW
Adjustment
1. Press the system menu key.
2. Press the start key to output an A3/Ledger test pattern.
Description
Description
MP motor (MPM)
Eject motor (EM)
Job eject motor (JEM) (option)
Fuser motor (FUM)
Duplex motor (DUM)
Paper conveying motor (PCM)
Description
Drum motor K (DRM-K) full speed
Description
Developing motor K (DEVM-K)
Transfer motor (TRM) full speed
Registration motor (RM)
Polygon motor (PM) full speed
Description
MP motor (MPM)
Eject motor (EM)
Job eject motor (JEM) (option)
Fuser motor (FUM)
Duplex motor (DUM)
Figure 1-3-7
Setting range
-500 to 500
-500 to 500
-500 to 500
-500 to 500
-500 to 500
-500 to 500
Setting range
-500 to 500
Setting range
-500 to 500
-500 to 500
-500 to 500
-500 to 500
-500 to 500
Setting range
-500 to 500
-500 to 500
-500 to 500
-500 to 500
-500 to 500
Correct values for an A3/Ledger output are:
±
A = 350
0.5 mm
±
B = 250
0.5 mm
2JZ/2JX/2JV/2H7-5
Initial setting
0
0
300
/325
*1
*2
150
/0
*1
*2
0
0
/-50
*1
*2
Initial setting
17
/20
/27
*1
*2
*3
Initial setting
0
0
50
50
0
Initial setting
0
0
300
380
0
1-3-35

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

250ci400ci500ci

Table of Contents