2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Resetting partial operation control
U906
Description
Resets the service call code for partial operation control.
Purpose
To be reset after partial operation is performed due to problems in the cassettes or other sections, and the
related parts are serviced.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key to reset partial operation control.
4. Turn the main power switch off and on.
Checking the total counter value
U908
Description
Displays the total counter value.
Purpose
To check the total counter value.
Method
1. Press the start key. The screen for total count value is displayed.
Display
Total Count
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Clearing the coverage data
U910
Description
Clears the accumulated data for the digital dot coverage per A4 size paper in all colors.
Purpose
To clear data as required at times such as during maintenance service.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key. The digital dot coverage data is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-148
Description
Description
Total count value