Maintenance
item No.
Setting toner near end detection
U136
Description
Sets the level that indicates the number of sheets that can be printed from occurrence of toner near end to
toner empty.
Purpose
To change the setting to advance detection of near end if the interval from toner near end to toner empty
seems too short.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the value using the +/- or numeric keys.
Display
BK
CMY
Increasing the setting makes the interval from toner near end to toner empty longer.
Decreasing the setting makes the interval from toner near end to toner empty shorter.
If 0 is set, toner near end will not be detected.
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Displaying the temperature and humidity outside the machine
U139
Description
Displays the detected temperature and humidity outside the machine.
Purpose
To check the temperature and humidity outside the machine.
Method
1. Press the start key. The detected temperature and humidity are displayed.
Display
External Temperature
External Humidity
Internal Temp1 (LSU)
Internal Temp2
Internal Temp3
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Setting the level of black toner
Setting the level of cyan/magenta/yellow toner
Description
External temperature (
External humidity (
Internal temperature around the laser scanner unit (
Internal temperature around the transfer section (
Internal temperature around the developing section (
Setting
range
0 to 9
0 to 9
C)
)
2JZ/2JX/2JV/2H7-5
Initial
setting
3
3
C)
C)
C)