Kyocera 300ci Service Manual page 225

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

Section
Jam code
Optional
71
DP
An original jam in
the original feed
section
72
An original jam in
the original con-
veying section
73
An original jam in
the original regis-
tration section
74
An original jam in
the original feed
section
75
An original jam in
the original con-
veying section
76
An original jam in
the original switch-
back section 1
77
An original jam in
the original switch-
back section 2
Conditions
The original registration switch (ORSW) does not
turn on within specified time of the original feed
switch (OFSW) turning on.
DP timing switch 1 (DPTSW1) turns off within the
specified time since the switch turns on.
During single scanning, the DP timing switch 1
(DPTSW1) does not turn on within specified time of
the original registration switch (ORSW) turning on
(Retry 5 times).
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn on within specified
time of the original registration switch (ORSW) turn-
ing on (Retry 5 times).
During dual scanning, the DP timing switch 2
(DPTSW2) does not turn on within specified time of
the original registration switch (ORSW) turning on
(Retry 5 times).
The original feed switch (OFSW) or original registra-
tion switch (ORSW) does not turn off within specified
time of the DP timing switch 1 (DPTSW1) turning on.
Scanning of previous original is not complete when
DP timing switch 1 (DPTSW1) turns on.
During single scanning, the DP timing switch 1
(DPTSW1) does not turn off within specified time of
the original registration switch (ORSW) turning off.
During duplex switchback scanning, the DP timing
switch 1 (DPTSW1) does not turn off within specified
time of the original registration switch (ORSW) turn-
ing off.
During dual scanning, the DP timing switch 2
(DPTSW2) does not turn off within specified time of
the original registration switch (ORSW) turning off.
During duplex switchback scanning, the switchback
tray switch (SBTSW) does not turn on within speci-
fied time of the DP timing switch 1 (DPTSW1) turn-
ing on.
During duplex switchback scanning, the original reg-
istration switch (ORSW) does not turn on within
specified time since original switchback operation
starts.
2JZ/2JX/2JV/2H7
Specified time
40/40 ppm
25/25 ppm
50/40 ppm
50/40 ppm
30/30 ppm
Color
914 ms
557 ms
557 ms
914 ms
557 ms
557 ms
1774 ms
1080 ms
1080 ms
1774 ms
1080 ms
1080 ms
1014 ms
617 ms
617 ms
2084 ms
1268 ms
1268 ms
-
-
-
1416 ms
862 ms
862 ms
1416 ms
862 ms
862 ms
656 ms
400 ms
400 ms
2318 ms
1411 ms
1411 ms
935 ms
569 ms
569 ms
B/W
1-4-7