Kyocera 300ci Service Manual page 171

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

Maintenance
item No.
Setting: [DP]
U425
1. Measure the distance from the leading edge to the black belt (inside) of the original at A.
2. Enter the measured value using the +/- keys in [LEAD].
3. Measure the distance from the left edge to the black belt (inside) of the original at B.
4. Enter the measured value using the +/- keys in [MAIN SCAN].
5. Measure the distance from the black belt of leading edge (inside) to the black belt of trailing edge
(inside) of the original at C.
6. Enter the measured value using the +/- keys in [SUB SCAN].
7. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
B
C
Original for adjustment (P/N: 302AC68243)
Figure 1-3-28
2JZ/2JX/2JV/2H7-5
A
1-3-125