Kyocera 300ci Service Manual page 104

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Setting: [Set Charger Freq]
U100
1. Select the item to be set.
2. Change the value using the +/- or numeric keys.
Display
Charger Freq
Charger Freq
B/W*
*: 50/40 ppm model only.
3. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt copying mode
(which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for maintenance item No. is displayed.
Setting the voltage for the primary transfer
U101
Description
Sets the control voltage for the primary transfer.
Purpose
To change the setting when any density problems, such as too dark or light, occur.
Setting
1. Press the start key.
2. Select the item to be set.
3. Change the value using the +/- or numeric keys.
Display
Normal (Full M)
Normal (Half M)
Reverse (B/W M)
Add Color (C)
Add Color (Y)
Add Color (K)
Add Color 2nd(C)
Add Color 2nd(M) Addition value for the second side (magenta) -127 to 127
Add Color 2nd(Y)
Add Color 2nd(K)
Surround
Correct
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
4. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt copying mode
(which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for maintenance item No. is displayed.
1-3-58
Description
Description
Main charger frequency
Main charger frequency in black/white
mode
Description
Primary transfer positive voltage for magenta
(full speed)
Primary transfer positive voltage for magenta
(half speed)
Primary transfer reverse voltage for magenta
in black/white mode
Addition value (cyan)
Addition value (yellow)
Addition value (black)
Addition value for the second side (cyan)
Addition value for the second side (yellow)
Addition value for the second side (black)
Environmental correction
ON/OFF setting
Setting range
Initial setting
0 to 65535
31449
0 to 65535
31449
Setting range Initial setting
0 to 255
105
/95
*1
0 to 255
78
/75
*1
0 to 255
105
-127 to 127
5
-127 to 127
5
-127 to 127
20
/15
*1
-127 to 127
0
0
-127 to 127
0
-127 to 127
-15
/-10
*1
0 (on)/1 (off)
0
*2
*2
*2
*2

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: