Kyocera 300ci Service Manual page 406

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7
Connector
Pin No.
YC20
B2
Connected
B3
to the feed
B4
PWB
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
B17
B18
B19
B20
YC21
1
Connected
2
to the feed
3
PWB
4
5
6
7
8
YC22
1
Connected
2
to the feed
3
PWB
4
(40/40,
50/40 ppm
5
model)
6
2-3-18
Signal
I/O
FED1 CLT REM
O
REG JAM
I
LSU SOL DR
O
MPF2 JAM
I
FEED1 JAM
I
ROL UP2 CLT
O
REM
REG UP1 CLT
O
REM
LOOP SENS
I
BELT JAM
I
DU ENTER JAM
I
JAM1 LED
O
JAM2 LED
O
COV FAN REM
O
DU OPEN
I
DU JAM
I
FEED3 JAM
I
FEED2 JAM
I
CAS OPEN
I
DU MT PD
O
+24V2
O
+24V2
O
+24V2
O
PGND
-
PGND
-
PGND
-
PGND
-
+5V1
O
REG MT CLK
O
REG MT DR
O
REG MT PD
O
ROL MT CLK
O
ROL MT DR
O
ROL MT PD
O
Voltage
0/24 V DC
PFCL1: On/Off
0/3.3 V DC
RSW: On/Off
0/24 V DC
LSUCSOL: On/Off
0/3.3 V DC
MPPCSW: On/Off
0/3.3 V DC
FSW1: On/Off
0/24 V DC
MCL: On/Off
0/24 V DC
RCL: On/Off
0/3.3 V DC
LS: On/Off
0/3.3 V DC
JDS: On/Off
0/3.3 V DC
FSSW: On/Off
0/3.3 V DC
JLEDPWB1 LED emitter signal
0/3.3 V DC
JLEDPWB2 LED emitter signal
0/24 V DC
PCFM1,2: On/Off
0/3.3 V DC
LC1SW: On/Off
0/3.3 V DC
DUSW: On/Off
0/3.3 V DC
FSW3: On/Off
0/3.3 V DC
FSW2: On/Off
0/3.3 V DC
LC2SW: On/Off
0/3.3 V DC
DUM current control signal
24 V DC
24 V DC power to FPWB
24 V DC
24 V DC power to FPWB
24 V DC
24 V DC power to FPWB
-
Ground
-
Ground
-
Ground
-
Ground
5 V DC
5 V DC power to FPWB
0/3.3 V DC (pulse) RM clock signal
0/3.3 V DC
RM: On/Off
0/3.3 V DC
RM current control signal
0/3.3 V DC (pulse) MM clock signal
0/3.3 V DC
MM: On/Off
0/3.3 V DC
MM current control signal
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

250ci400ci500ci

Table of Contents