2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Completion
U108
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking the drum type
U109
Description
Displays the drum sensitivity data.
Purpose
To check the drum sensitivity data.
Method
1. Press the start key.
2. Select the item.
Display
CYAN(Dark)
MAGENTA(Dark)
YELLOW(Dark)
BLACK(Dark)
CYAN(Light)
MAGENTA(Light)
YELLOW(Light)
BLACK(Light)
The drum sensitivity data is displayed.
Display
DATA1 - DATA11
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Checking the drum count
U110
Description
Displays the drum counts for checking.
Purpose
To check the drum status.
Method
1. Press the start key. The current drum counts is displayed.
Display
Drum counter (CYAN)
Drum counter (MAGENTA)
Drum counter (YELLOW)
Drum counter (BLACK)
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-66
Description
Description
Drum sensitivity data for cyan (dark potential)
Drum sensitivity data for magenta (dark potential)
Drum sensitivity data for yellow (dark potential)
Drum sensitivity data for black (dark potential)
Drum sensitivity data for cyan (light potential)
Drum sensitivity data for magenta (light potential)
Drum sensitivity data for yellow (light potential)
Drum sensitivity data for black (light potential)
Description
Drum sensitivity data
Description
Cyan drum count value
Magenta drum count value
Yellow drum count value
Black drum count value