Kyocera 300ci Service Manual page 102

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-6
Maintenance
item No.
Adjusting main high voltage
U100
Description
Controls the charger roller voltage to optimize the surface potential.
Purpose
To change the setting value to adjust the image if an image failure (background blur, etc.) occurs.
Method
1. Press the start key.
2. Select an item and press the start key. The screen for executing each item is displayed.
Display
Adjust MC AC Bias
AC Auto Adjustment
Set DC1
Adjust DC2
Adjust DC2(B/W)
Low Temp. Setting (Drum) Pre-charge time at power supply ON
Set Charger Freq
Setting: [Adjust MC AC Bias]
1. Change the value using the +/- or numeric keys.
Increasing the setting makes the image lighter; decreasing it makes the image darker.
The values set vary depending on environments.
Display
MC AC Bias(C)
MC AC Bias(M)
MC AC Bias(Y)
MC AC Bias(K)
MC AC Bias(K)BW*
*: 50/40 ppm model only.
2. Press the start key. The value is set.
Setting: [AC Auto Adjustment]
1. Select ON or OFF.
Display
ON
OFF
Initial setting: ON
2. Press the start key. The setting is set.
1-3-56
Description
Description
Main charger AC bias for each color
Setting the AC bias auto adjustment
Main charger DC bias for each color
Additional surface potential
Additional surface potential in black and white mode
Setting the main charger frequency
Description
Main charger AC bias for cyan
Main charger AC bias for magenta
Main charger AC bias for yellow
Main charger AC bias for black
Main charger AC bias for black in black/white mode
Description
Turns auto adjustment ON
Turns auto adjustment OFF
Setting range
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255

Hide quick links: