2JZ/2JX/2JV/2H7-6
Maintenance
item No.
Setting: [SetCalib Timing duringPrint]
U464
1. Change the setting value using the +/- keys.
Display
Timing(sec)
2. Press the start key. The value is set.
Setting: [Set Interval CalibDriveTime]
1. Change the setting value using the +/- keys.
Display
Time(sec)
2. Press the start key. The value is set.
Setting: [Set Interval CalibPrintRate]
1. Change the setting value using the +/- or numeric keys.
Display
Threshold Level(%)
2. Press the start key. The value is set.
Setting: [Set Custom]
1. Select ON or OFF.
Display
ON
OFF
Initial setting: OFF
2. Press the start key. The setting is set.
Setting: [AC Calibration]
1. Select the color of the replaced developing unit or drum unit.
Display
CYAN
MAGENTA
YELLOW
BLACK
High Altitude
2. Press ON/OFF.
If the machine is installed at high altitude, select [High Altitude].
3. Press the start key. AC calibration is executed.
4. When normally completed, [Complete] is displayed.
When an error occurs, an error code is displayed.
5. Turn the main power switch off and on.
1-3-130
Description
Setting the drive standard time of contin-
uous print
Description
Setting the drive standard time
Description
Setting the standard printing ratio
Description
Set to custom settings in setting the calibration cycle under the system menu
Set to standard settings in setting the calibration cycle under the system menu
Description
Developing unit C or drum unit C
Developing unit M or drum unit M
Developing unit Y or drum unit Y
Developing unit K or drum unit K
Overall setting for installation at high altitude
Description
Setting range
300 to 3600 (s) 1800
Setting range
300 to 3000 (s) 600
Setting range
0 to 100 (%)
Initial setting
Initial setting
Initial setting
20