Maintenance
item No.
Setting: [Set Drum Cleaning Mode]
U147
Modify settings only if faulty images, such as smear, occurs in a high humid environment.
1. Select the mode to be set.
Display
MODE1
MODE2
Initial setting: MODE1
2. Press the start key. The setting is set.
Setting: [Set Minimum Value]
1. Change the setting value using the +/- keys.
Display
Minimum Value
The initial setting value depends on the setting of [Set Drum Cleaning Mode].
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Setting drum refresh mode
U148
Description
Selects the mode used in drum refreshing
Purpose
Change settings when drum refreshing is too frequently executed.
Setting
1. Press the start key.
2. Select ON or OFF.
Display
OFF
ON
Initial setting: ON
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Constitutes a toner layer if the print coverage is less than 2%.
(excludes the maximum paper width A3/A4)
Apply toner regardless of the current print coverage.
Description
Toner layer width (mm)
Description
Drum refreshing is not performed
Drum refreshing is performed
2JZ/2JX/2JV/2H7-5
Setting range
Initial setting
0 to 30 (mm)
MODE1: 10
MODE2: 20