Kyocera 300ci Service Manual page 452

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

Adjusting
Item
order
Adjusting magnification of the
scanner in the auxiliary scanning
11
direction (scanning adjustment)
Adjusting the center line (scanning
adjustment)
12
Adjusting the leading edge registra-
tion (scanning adjustment)
13
Adjusting the leading edge margin
(scanning adjustment)
14
Adjusting the trailing edge margin
(scanning adjustment)
15
Adjusting the left and right margins
(scanning adjustment)
16
When maintenance item U411 (
Automatic adjustment in the scanner
the following adjustments are automatically made:
Adjusting the scanner magnification (U065)
Adjusting the scanner leading edge registration (U066)
Adjusting the scanner center line (U067)
When maintenance item U411 (
Automatic adjustment in the DP
the following adjustments are automatically made:
Adjusting the DP magnification (U070)
Adjusting the DP leading edge registration (U071)
Adjusting the DP center line (U072)
Image
Description
Original scanning speed
Adjusting the original scan data
(image adjustment)
Original scan start timing
Adjusting the original scan data
(image adjustment)
Adjusting the original scan data
(image adjustment)
Adjusting the original scan data
(image adjustment)
) is run using the specified original (P/N 302FZ56990),
) is run using the specified original (P/N 302AC68243),
Maintenance mode
Original
Item No.
Mode
U065
SUB SCAN ADJ
Test chart
U070
CONVEY SPEED1
CONVEY SPEED2
CIS SUB ADJ
U067
ADJUST DATA1
Test chart
ADJUST DATA2
U072
ADJUST DATA1
ADJUST DATA2
ADJUST DATA3
U066
ADJUST DATA1
Test chart
ADJUST DATA2
U071
ADJUST DATA1
ADJUST DATA3
ADJUST DATA5
U403
B MARGIN
Test chart
U404
B MARGIN
U403
D MARGIN
Test chart
U404
D MARGIN
U403
A MARGIN
Test chart
C MARGIN
U404
A MARGIN
C MARGIN
Image quality
Item
100% magnification
Machine: ±0.8%
Using DP: ±1.5%
Enlargement/reduction
Machine: ±1.0%
Using DP: ±1.5%
Lateral squareness
Machine: ±1.5 mm/375 mm
Using DP: ±2.5 mm/375 mm
Leading edge registration
Cassette: +1.0/-1.5 mm
MP tray: +1.0/-1.5 mm
Duplex: +1.0/-1.5 mm
Skewed paper feed
Cassette: 1.5 mm or less
(left-right difference)
MP tray: 1.5 mm or less
Duplex: 2.0 mm or less
Lateral image shifting
Cassette: ±2.0 mm
MP tray: ±2.0 mm
Duplex: ±3.0 mm
Page
Remarks
P.1-3-39
U065: For copying an original placed on
the contact glass
P.1-3-43
U070: For copying originals from the DP.
To make an adjustment for duplex copying, select
CONVEY SPEED2 or CIS SUB ADJ.
P.1-3-41
U067: For copying an original placed on
the contact glass
To make an adjustment for rotate copying, select
ADJUST DATA2.
P.1-3-46
U072: For copying originals from the DP.
To make an adjustment for duplex copying, select
ADJUST DATA2 or ADJUST DATA3.
P.1-3-40
U066: For copying an original placed on
the contact glass
P.1-3-44
To make an adjustment for trailing edge registra-
tion, select ADJUST DATA2.
U071: For copying originals from the DP.
To make an adjustment for duplex copying, select
ADJUST DATA3 or ADJUST DATA5.
P.1-3-115
U403: For copying an original placed on
the contact glass
P.1-3-116
U404: For copying originals from the DP.
P.1-3-115
U403: For copying an original placed on
the contact glass
P.1-3-116
U404: For copying originals from the DP.
P.1-3-115
U403: For copying an original placed on
the contact glass
P.1-3-116
U404: For copying originals from the DP.
Specifications
2JZ/2JX/2JV/2H7-6
2-4-10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

250ci400ci500ci

Table of Contents