23. Connect the connector of the key counter
wire to the connector YC36 on the engine
PWB.
24. Release five wire saddles and then fasten
the key counter wire.
25. Refit all the parts removed in steps 22 to 8.
26. Release two wire saddles and then fasten
the key counter wire.
27. Carry out wiring of key counter wire on the
wire guide.
Engine PWB
Wire saddle
Wire saddle
Key counter wire
(302H746930)
Wire saddle
Wire saddle
Key counter wire
(302H746930)
2JZ/2JX/2JV/2H7-1
Connector (YC36)
Connector
Key counter wire
(302H746930)
Wire saddle
Wire saddle
Wire saddle
Figure 1-2-25
Wire guide
Figure 1-2-26
Engine PWB