Connector
Pin No.
YC5
1
Connected
2
to the clean-
3
ing lamp C,
4
drum PWB
C and drum
5
position
6
sensor C
7
8
9
10
11
YC6
1
Connected
2
to the devel-
3
oping PWB
4
C
5
6
7
YC7
1
Connected
2
to the clean-
3
ing lamp M,
4
drum PWB
M and drum
5
position
6
sensor M
7
8
9
10
11
YC8
1
Connected
2
to the devel-
3
oping PWB
4
M
5
6
7
Signal
I/O
ERASER C
O
ERS DR
O
+3.3V1
O
EEP SCL
O
EEPSDA
I/O
GND
-
A1(OPEN)
-
A0(GND)
-
5V1
O
POS SENS 2
I
GND
-
GND
-
SDA
I/O
SCK
O
+3.3V1
O
TPD2
I
24V1
O
VCONT 2
O
ERASER M
O
ERS DR
O
+3.3V1
O
EEP SCL
O
EEPSDA
I/O
GND
-
A0(GND)
-
A0(GND)
-
5V1
O
POS SENS 1
I
GND
-
GND
-
SDA
I/O
SCK
O
+3.3V1
O
TPD1
I
24V1
O
VCONT 1
O
Voltage
24 V DC
24 V DC power to CL-C
24/0 V DC
CL-C: On/Off
3.3 V DC
3.3 V DC power to DRPWB-C
0/3.3 V DC (pulse) DRPWB-C EEPROM clock signal
0/3.3 V DC (pulse) DRPWB-C EEPROM data signal
-
Ground
-
Not used
-
Ground
5 V DC
5 V DC power to DPS-C
0/3.3 V DC
DPS-C: On/Off
-
Ground
-
Ground
0/3.3 V DC (pulse) DEVPWB-C EEPROM data signal
0/3.3 V DC (pulse) DEVPWB-C EEPROM clock signal
3.3 V DC
3.3 V DC power to DEVPWB-C
Analog
TS-C detection signal
24 V DC
24 V DC power to DEVPWB-C
Analog
TS-C control signal
24 V DC
24 V DC power to CL-M
24/0 V DC
CL-M: On/Off
3.3 V DC
3.3 V DC power to DRPWB-M
0/3.3 V DC (pulse) DRPWB-M EEPROM clock signal
0/3.3 V DC (pulse) DRPWB-M EEPROM data signal
-
Ground
-
Ground
-
Ground
5 V DC
5 V DC power to DPS-M
0/3.3 V DC
DPS-M: On/Off
-
Ground
-
Ground
0/3.3 V DC (pulse) DEVPWB-M EEPROM data signal
0/3.3 V DC (pulse) DEVPWB-M EEPROM clock signal
3.3 V DC
3.3 V DC power to DEVPWB-M
Analog
TS-M detection signal
24 V DC
24 V DC power to DEVPWB-M
Analog
TS-M control signal