Kyocera 300ci Service Manual page 310

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-1
14. Remove the sponge from the wire guide and
release the wire.
15. Move the mirror 1 frame to notch position.
16. Release the wire holder and then remove
the wire.
17. Remove the screw and remove the expo-
sure lamp from mirror 1 frame.
18. Check or replace the exposure lamp and
then install the lamp.
19. Refit all the removed parts.
1-5-14
Wire holder
Wire
Mirror 1 frame
Exposure lamp
Mirror 1
frame
Wire
Mirror 1 frame
Wire guide
Figure 1-5-24
Screw
Mirror 1 frame
Figure 1-5-25
Sponge
Exposure
lamp