2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Setting: [SetInt.Calib PrintRate(H)]
U464
1. Change the setting value using the +/- or numeric keys.
Display
Threshold Level(%)
2. Press the start key. The value is set.
Setting: [Set Calib TimingduringPrint(H)]
1. Change the setting value using the +/- keys.
Display
Timing(sec)
2. Press the start key. The value is set.
Setting: [AC Calib Type]
1. Select MODE1 or MODE2.
Display
MODE1
MODE2
Initial setting: MODE1
2. Press the start key. The setting is set.
Setting: [Warmup Calib Type]
1. Select MODE1 or MODE2.
Display
MODE1
MODE2
Initial setting: MODE1
2. Press the start key. The setting is set.
Completion
Press stop key. The screen for selecting a maintenance item No. is displayed.
1-3-132
Description
Description
Setting the standard printing ratio
Description
Setting the drive standard time of contin-
uous print
Description
Execute AC calibration by normal bias control
Execute AC calibration by fixed bias value
Description
Execute simple calibration for 25/25, 30/30 ppm model at startup.
Execute regular calibration for 40/40, 50/40 ppm model at startup.
Setting range
Initial setting
0 to 100 (%)
10
Setting range
Initial setting
300 to 3600 (s) 600