Kyocera 300ci Service Manual page 166

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Method: DP(FACE UP)
U411
1. Measure the leading edge, main scanning, and auxiliary scanning of the specified original (P/N:
302AC68243) and enter the values by executing maintenance item U425.
2. Set a specified original (P/N: 302AC68243) in the DP. Cut the trailing edge of the original.
3. Press [INPUT].
Display
INPUT
4. Press the start key. Auto adjustment starts.
When automatic adjustment has normally completed, [COMPLETE] is displayed. If a problem occurs dur-
ing auto adjustment, [ERROR XX] (XX is replaced by an error code) is displayed and operation stops.
Should this happen, determine the details of the problem and either repeat the procedure from the begin-
ning, or adjust the remaining items manually by running the corresponding maintenance items.
Method: DP(FACE DOWN)
1. Place the specified original for acquiring gamma target data (P/N: 303JX57010) on the platen, and press
the start key.
2. Place the specified original for acquiring matrix target data (P/N: 303JX57020) on the platen, and press
the start key.
When normally completed, [COMPLETE] is displayed.
3. Select the item (place all originals face down).
Display
ALL
INPUT
MTF/GAMMA
MATRIX
[INPUT]
1. Select [INPUT].
2. Place a specified original (P/N: 302AC68243).
3. Press the start key. Auto adjustment starts.
[GAMMA]
1. Select [MTF/GAMMA].
2. Place a specified original (P/N: 303JX57010).
3. Press the start key. Auto adjustment starts.
[MTF/MATRIX]
1. Select [MATRIX].
2. Place a specified original (P/N: 303JX57020).
3. Press the start key. Auto adjustment starts.
1-3-120
Description
Figure 1-3-26
Description
Automatic adjustment of first page using the DP for: original size mag-
nification/leading edge timing/center line.
Description
Automatic adjustment of second page using the
DP for: original size magnification/leading edge
timing/center line, input gamma, chromatic
aberration filter, MTF filter and matrix.
Automatic adjustment of second page using the
DP for: original size magnification/leading edge
timing/center line.
Automatic adjustment of second page using the
DP for: MTF filter and input gamma.
Automatic adjustment of second page using the
DP for: matrix.
5 mm
149 ± 1 mm
74 ± 1 mm
Original to be used for
adjustment (P/N)
302AC68243/303JX57010/
303JX57020
302AC68243
303JX57010
303JX57020

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

250ci400ci500ci

Table of Contents