Kyocera 300ci Service Manual page 156

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Setting the cassette heater control
U327
Description
Sets the cassette heater control.
Purpose
To change the setting according to the machine installation environment.
Method
1. Press the start key.
2. Select the item.
Display
MODE Setting
Option Heater
Setting: [MODE Setting]
1. Select the item.
Display
OFF
MODE1
MODE2
Initial setting: OFF
2. Press the start key. The setting is set.
Setting: [Option Heater]
1. Select the item.
Display
NONE
EXISTS
Initial setting: NONE
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Side ejection setting
U328
Description
Sets whether to eject to the side of the machine when an optional curl eliminator is installed.
Purpose
Set according to the preference of the user.
Setting
1. Press the start key.
2. Select ON or OFF.
Display
ON
OFF
Initial setting: OFF
3. Press the start key. The setting is set.
4. Turn the main power switch off and on.
1-3-110
Description
Description
Setting the cassette heater control
Optional cassette heater installed/not Installed setting
Description
Cassette heater OFF
Cassette heater ON during sleep mode
Cassette heater ON during sleep mode and standby
Description
Optional cassette heater not Installed
Optional cassette heater installed
Description
To eject to the side of the machine
Not to eject to the side of the machine

Hide quick links: