Maintenance
item No.
Checking LSU cleaning operation
U474
Description
Provides cleaning LSU by means of the LSU cleaning clutch and LSU cleaning solenoid. Also, the cleaning
cycle can be adjusted.
Method
1. Press the start key.
2. Select the item.
Display
Cleaning Operation
Cleaning Cycle
Cleaning Setting
Method: [Cleaning Operation]
1. Select [Cleaning Operation].
2. Press the start key. Cleaning the LSU slit glass.
Setting: [Cleaning Cycle]
1. Select [Cleaning Cycle].
2. Change the setting value using +/- keys.
Display
Cleaning Cycle
The setting can be changed by 1000 per step.
3. Press the start key. The value is set.
Setting: [Cleaning Setting]
1. Change the setting using the +/- keys.
Display
0
1
Initial setting: 1
2. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Executing the cleaning operation
Setting the cleaning cycle
Setting the cleaning operation
Description
Cleaning cycle
Description
LSU cleaning operation is not executed at startup or sleep recovery.
LSU cleaning operation is executed at startup and sleep recovery.
2JZ/2JX/2JV/2H7-5
Setting range
Initial setting
0 to 5000
1000