Kyocera 300ci Service Manual page 108

Kyocera 250ci; 300ci; 400ci; 500ci office mfp
Hide thumbs Also See for 300ci:
Table of Contents

Advertisement

2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Setting: [OHP]
U106
1. Change the value using the +/- or numeric keys.
Display
Width<220
220<=Width
*1: 40/40, 50/40 ppm model *2: 25/25, 30/30 ppm model
2. Press the start key. The value is set.
Setting: [Bias]
1. Change the value using the +/- or numeric keys.
Display
Reverse(Full)
Reverse(Half)
Cleaning(Full)
Cleaning(Half)
Cleaning(BW)
2. Press the start key. The value is set.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt copying mode
(which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-62
Description
Description
Small and medium sizes (under 220 mm
wide)
Large sizes (more than 220 mm wide)
Description
Transfer bias when plain paper is used
Transfer bias when thick paper is used
Cleaning control value when plain paper is
used
Cleaning control value when thick paper is
used
Cleaning control value in black and white
mode
Setting range
Initial setting
0 to 255
123
/97
*1
0 to 255
51
/44
*1
*2
Setting range
Initial setting
0 to 255
189
0 to 255
189
0 to 255
34
0 to 255
34
0 to 255
34
*2