2JZ/2JX/2JV/2H7-5
Maintenance
item No.
Setting transfer high-voltage timing
U128
Description
Adjusts the ON/OFF timing of transfer high-voltage output.
Purpose
Basically, the setting need not be changed. If any problem such as faulty images or dirt on the back surface
occurs, change the setting.
Method
1. Press the start key.
2. Select the item to set.
3. Change the value using the +/- or numeric keys.
Display
Trans ON Timing1
Trans ON Timing2
Trans OFF Timing
4. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
1-3-70
Description
Description
Transfer ON timing adjustment value
(first side)
Transfer ON timing adjustment value
(second side)
Transfer OFF timing adjustment value
Setting range
Initial setting
-200 to 200
-54
-200 to 200
-54
-200 to 200
10