Potential Control Timing) - Canon 1130 Service Manual

Color laser copier
Hide thumbs Also See for 1130:
Table of Contents

Advertisement

CHAPTER 6 IMAGE FORMATION SYSTEM
E061
Check
Dark area
potential
attenuation
limit
Control
limit
Measure-
ment
limit
VDI: Potential measured during initial rotation.
Vd3: Post-cleaning charging area potential as measured when the dark area
Offset value: Value determined in service mode (FUNCTION>DPC>OFST).
6-16
COPYRIGHT © 2002 CANON INC.
Detail
code
0060
The dark area potential
attenuation value is 150 V or
more.
0070
The grid bias output is 900 V or
more.
0071
The developing bias output is
100 V or less.
xx80
The developing bias output is
700 V or more.
xx81
The developing bias output is
200 V or less.
0090
Vd1 is 650 V or more.
0091
VL1 is 200 V or more.
0092
Vd2 is 850 V or more.
0093
VL2 is 250 V or more.
0094
Vd1 is 350 V or less.
0095
VL1 is 10 V or less.
0096
Vd2 is 550 V or less.
0097
VL2 is 50 V or less.
attenuation is measured.
CANON CLC1100/1130/1150/1160/1180 REV.3 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
Description
Possible cause
Photosensitive drum; error in
potential control.
The grid bias upper limit is
reached.
The grid bias lower limit is
reached.
The developing bias upper
limit is reached.
The developing bias lower
limit is reached.
The Vd1 upper limit his
reached, or the
photosensitive drum has
deteriorated.
The VL1 upper limit is
reached.
The Vd2 upper limit is
reached.
The VL2 upper limit is
reached.
The Vd1 lower limit is
reached.
The VL1 lower limit is
reached.
The Vd2 lower limit is
reached.
The VL2 lower limit is
reached.

Hide quick links: