CHAPTER 9 EXTERNALS / AUXILIARY MECHANISMS
The typical models in relation to the various SSTs are as follows:
Model name
CLC1120/1130/1150 CLC1100S
CLC1100
CLC1140/1160/1180 CLC1180
To select a specific CPU on the CPU PCB using an SST, use the following unit name:
In addition to downloading firmware, the SST enables uploading or downloading of backup
data. When replacing the CPU PCB, use these functions to transfer the backup data stored on the
existing PCB.
The backup data from the three CPUs cannot be uploaded or downloaded all at once, requiring
work on a unit basis.
The parallel port for downloading is controlled by JCON, and communication to other CPUs is
by way of JCON. When starting downloading, you must select the target CPU; once you have made
a selection, you will not be able to change it in the middle of operation. If you want to connect to a
different CPU, you will have to turn off and then on the power switch, thereby re-starting the
machine.
9-2b
COPYRIGHT © 2002 CANON INC.
Typical model name in relation to SST
CLC1100
Table 9-201
CPU name
Unit name in relation to SST
DC-CPU
DCON
R-CPU
JCON
PANEL-CPU
MCON
Table 9-202
CANON CLC1100/1130/1150/1160/1180 REV.0 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)