5. Removing the Post-Cleaning
Charging Assembly
1) Open the hopper unit fully.
2) Remove the screw [1], and detach the
post-cleaning assembly [2].
6. Adjusting the Height of the
Charging Wire
The height of the charging wire may be
adjusted by turning the screw found at the
back of the charging assembly. A full turn of
the screw shifts the position of the charging
wire by about 0.7 mm.
The height of the charging wire of the
internal static eliminator, external charge
eliminator, separation charging assembly or
the post-cleaning charging assembly,
however, cannot be adjusted.
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.1 JAN. 2000 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 IMAGE FORMATION SYSTEM
[2]
Figure 6-625
Charging
Height of charging
assembly
wire (mm)
Primary
10.5
charging
assembly
Separa-
tion
charging
assembly
External
charging
eliminator
17.0
Figure 6-626
[1]
Range of
adjustment
4 mm
(approx.)
6-63