CHAPTER 6 IMAGE FORMATION SYSTEM
•
If CLC1100/1120/1130/1150
4) Remove the 2 screws [4], and take
out the black toner concentration
sensor from the unit; then, disconnect
the connector [5].
•
If CLC1140/1160/1180
4) Remove the 2 screws [6].
5) Remove the 2 screws [4], and take out
the black toner concentration sensor
from the unit; then, disconnect the
connector [5].
6-81a
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.0 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
[4]
[5]
Figure 6-674b
[6]
Figure 6-674c
[4]
[5]
Figure 6-674d