3) Adjust the left/right registration adjusting
plate so that the horizontal registration is
2.0 ± 15. mm in reference to the image.
5. Adjusting the Position of the Paper
Jogging Guide Sensor (PS40)
1) Select A4R or LTRR, and complete
copying on the first side of a double-sided
copy.
2) Slide out the duplexing unit.
3) Measure the distance L of the paper
jogging guide plate [1].
A4R:
L = 210 ± 0.3 mm
LTRR:
L = 216 ± 0.3 mm
4) If the distance is not as indicated, remove
the duplexing cover.
5) Loosen the screw [2].
6) Using the screw [3], adjust the position of
the paper jogging sensor.
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.1 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 7 PICK-UP / FEEDING SYSTEM
2.0 1.5mm
0
2
4
6
8
10
Figure 7-756
[L]
[1]
Figure 7-757
Figure 7-758
Figure 7-759
[1]
[2]
[1]
7-69