19) Press the copier's Start key, and check to
make sure LED3 [27] (pink) flashes each
time delivery occurs.
20) Attach the switch settings label [28] to the
top cover, and record the settings of the
switches.
21) Secure the top cover [1] in place with two
screws [2]. When doing so, check to make
sure that the cable is secured to the cable
guide inside the diagnostic device and is
not trapped by the top cover [1].
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.1 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 11 INSTALLATION
[27]
LED1 LED2 LED3
2
6
1
1
SW3
SW2
LED5
SW4
LED6
LED4
IC6
SW1
CN3
CN2
Figure 11-718
[1]
[2]
Figure 11-719
BAT1
1
2
CN4
[2]
[28]
11-45