III. CONTROLLING THE CHARGING MECHANISM
A. Controlling the Primary Charging Mechanism and the Grid Bias
1. Operation
The mechanism used to control the primary charging/grid bias of the primary charging
assembly has the following items of control:
1. Controlling primary charging to a constant current.
2. Controlling the grid bias to a constant voltage.
2. Protection Circuit
The overcurrent detection circuit is used as a grid bias protection circuit. If overcurrent occurs,
for example, as a result of a short circuit on the grid plate, the circuit will be turned off for about 0.1
sec and then will be reset automatically.
If a short circuit continues on the grid plate for some reason, all images will be error images.
Each of the signals is used for the following:
[1] HVPR (primary current activation signal)
When '1', high voltage is generated.
[2] HVGIC (grid bias activation signal)
When '1', a grid bias is ready for application.
[3] HVGI (grid bias level signal)
Controlled to +8 to +16 V; high voltage is generated at +16 V or less.
DC driver PCB
J1012
-A11
-A10
-A9
COPYRIGHT © 2002 CANON INC.
J411
[1]
HVPR
-3
[2]
HVGIC
-4
[3]
HVGI
Figure 6-301
CANON CLC1100/1130/1150/1160/1180 REV.0 MAR. 1999 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 IMAGE FORMATION SYSTEM
HVT-DC PCB
T302
J413
-5
Primary charging
Grid bias
Photosensitive
drum
6-17

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

112011001160118011401150

Table of Contents