CHAPTER 6 IMAGE FORMATION SYSTEM
· Shake the lubricant well
before application.
· Be sure to coat the side
as well as the edge of the
blade with lubricant.
· Use light strokes when
applying the lubricant to
avoid chipping by excess
force.
· Keep in mind that, if the
coating is not even,
copies can start to show
vertical white lines.
· Do not use alcohol or
solvent for cleaning.
Further, take care so that
the
photosensitive drum will
not come into contact
with solvent.
6) Dry wipe the window of the cleaner front
sensor.
7) Turn on the power switch so that the
copier will be in standby state.
8) Select and execute
FUNCTION>INSTALL>STIR-4 in
service mode.
9) Select and execute FUNCTION>SENS-
ADJ>CLN-OFST.
10) Record the value under ADJUST>SENS-
ADJ>CLN-THE, CLN-TMP on the
service label behind the right front cover.
11) Select and execute
FUNCTION>INSTALL>INIT-D in
service mode.
4. Cleaning the Photosensitive Drum
If the surface of the photosensitive drum
is soiled, wipe it with a flannel cloth coated
with toner. (Do not use paper, lint-free or
otherwise.)
Do NOT dry wipe or do
NOT clean with solvent.
Do
cleaning powder.
6-58
COPYRIGHT © 2002 CANON INC.
surface
of
the
NOT
use
drum
CANON CLC1100/1130/1150/1160/1180 REV.2 FEB. 2002 PRINTED IN JAPAN (IMPRIME AU JAPON)