Canon 1130 Service Manual page 690

Color laser copier
Hide thumbs Also See for 1130:
Table of Contents

Advertisement

17
E061
Cause
------------
------------
Potential sensor
unit
Pre-exposure
lamp
Primary charging
assembly
High-voltage
cable
COPYRIGHT © 2002 CANON INC.
Step
1
Is the setting of
COPIER>ADJUST>V-CONT-M/C/
Y/K in service mode identical to the
settings recorded on the service label?
2
Check the detail code in service
mode (COPIER>DISPLAY>ERR).
Is it 0000 or 0001?
Is it 0010?
Is it 0020?
Is it 0030, 0031, or 0032?
Is it 0040?
Is it 0050, 0051, 0052, or 0053?
Is it 0070, 0071, xx80, or xx81?
Is it 0060 or 009x?
3
Turn on and off the power switch.
Does LED1 on the potential
measurement PCB remain on
during potential control?
4
Does the pre-exposure lamp turn
on during copying operation?
5
Is the primary charging assembly
connected properly?
6
Is the primary charging wire
broken or soiled?
7
Are there traces of leakage on the
primary charging assembly?
8
Is there electrical conductivity
from the primary charging wire to
the high-voltage transformer
(HVT-DC)?
CANON CLC1100/1130/1150/1160/1180 REV.1 JAN. 2000 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 13 TROUBLESHOOTING
Checks
Yes/No
Action
NO
Enter the settings from
the service label newly.
YES
Go to step 3.
YES
Go to step 4.
YES
Go to step 5.
YES
Go to step 9.
YES
Go to step 12.
YES
Go to step 16.
YES
Go to step 19.
YES
Go to step 20.
NO
Replace the potential
sensor unit.
YES
Check the wiring from the
DC driver PC to the potential
sensor. Turn off and then on
the power switch; if the error
is indicated once again, go to
step 2.
NO
Check the wiring from
the DC driver PCB to
the pre-exposure lamp;
if normal, replace the
pre-exposure lamp.
YES
Check the potential
sensor unit. Turn off and
then on the power switch;
if the error is indicated
once again, go to step 2.
NO
Connect the assembly
properly.
YES
Clean or route the charging
wire once again. Turn off and
then on the power switch; if
the error is indicated once
again, go to step 2.
YES
Replace the primary
charging assembly.
NO
Check the primary high-
voltage cable.
YES
Replace the HVT-DC
PCB. Turn off and then
on the power switch; if
the error is indicated
once again, go to step 2.
13-113

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

112011001160118011401150

Table of Contents