9) Disconnect the connector A [7]; then,
move the lamp regulator unit slightly to
the front, and disconnect the connector B
[8] and the connector C [9], and detach the
lamp regulator PCB.
10) Disconnect the three connectors [10], and
free the harness [11] to the developing
drive assembly to the cable lamp.
11) Remove the two screws [12], and detach
the cable guide [13].
12) Free the harness [15] from the clamp [14].
COPYRIGHT © 2002 CANON INC.
CANON CLC1100/1130/1150/1160/1180 REV.1 JAN. 2000 PRINTED IN JAPAN (IMPRIME AU JAPON)
CHAPTER 6 IMAGE FORMATION SYSTEM
[9]
[8]
Figure 6-685
[11]
[10]
Figure 6-686
[12]
[13]
Figure 6-687
[7]
[14]
[15]
6-85