Category: Malfunction

■ Not able to remove the ITB Unit due to the Primary Transfer
Roller disengagement failure
[Location]
ITB Unit
[Cause/Condition]
If unexpected situations coincide with unexpected conditions, disengagement failure of the
Primary Transfer Roller may occur. As a result, the ITB Unit may not be able to be removed
from the host machine.
[Field Remedy]
Follow the procedure shown below to remove the ITB Unit from the host machine.
1) Open the Front Cover [1].
2) Open the Right Cover Unit [2].
3) Insert a flat-blade screwdriver into the hole [B].
4) Rotate the flat-blade screwdriver in a counterclockwise direction until it creates an opening
[A] between the Secondary Transfer Idler Roller Shaft Support [3] and the RD Sensor Stay
[4].
5) Remove the Drum Unit.
6) Remove the ITB Unit.