4) Select the folder containing the system software and click the "Search" button.
NOTE:
"XXXX" in the figure describes the version of system software.
5) A list of system software in the folder is displayed.
Deselect the checkbox of unnecessary folder(s) and/or system software and click the
"Register" button.
6) Click the "OK" button after the message telling completion of system software registration
is displayed.
6
Troubleshooting > Version Upgrade > Version Upgrade via SST > Connection
F-6-22
F-6-23
6
Troubleshooting > Version Upgrade > Version Upgrade via SST > Connection
■ Connection
The following IP address is automatically assigned for this machine at startup in download
mode.
• IP address: 172.16.1.100
• Subnet mask: 255.255.255.0
When the PC with SST installed is connected to this machine, change the PC network
address as follows:
• IP address: 172.16.1.160
• Subnet mask: 255.255.255.0
• Default gateway: arbitrary
CAUTION:
While the PC is connected to the network, changing to the abovementioned settings
may cause network failures due to an IP address conflict, etc. Ensure that the PC is
disconnected from the network when you change the PC network settings. Alternatively
use the cross cable to connect to this machine.
Preparation
Requirements
• PC with SST Ver.4.73 or later installed and the system software for this machine is
registered.
• Cross cable
10Base-T: Category 3 or 5
100Base-T: Category 5
1000Base-T: Enhanced Category 5 (CAT5e) or later
CAUTION:
Disconnect USB memory storage devices if connected.
This machine disables the communication to SST if any USB memory storage device is
recognized. SST and the USB memory storage device cannot be used concurrently.
6-22
6-22