Canon imageRUNNER ADVANCE C350 series Service Manual page 842

Table of Contents

Advertisement

COPIER> ADJUST> DENS
LLMT-PTM
Adj ATR Sensor (M)dens crrct lowr limit
Lv.2 Details
To adjust the lower limit of the target density correction (upper limit of
TD ratio) of the ATR Sensor (M).
As the value is decremented by 1, the lower limit of TD ratio is
increased by 0.5 %.
When the value is decreased, density is increased, but fogging/
scattering occurs.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
LLMT-PTC
Adj ATR Sensor (C)dens crrct lowr limit
Lv.2 Details
To adjust the lower limit of the target density correction (upper limit of
TD ratio) of the ATR Sensor (C).
As the value is decremented by 1, the lower limit of TD ratio is
increased by 0.5 %.
When the value is decreased, density is increased, but fogging/
scattering occurs.
Use case
When an image failure (density failure, fogging, carrier adherence,
and scattering, etc.) occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Take necessary action in accordance with the instructions from the
Quality Support Division.
Display/adj/set range
-5 to 5
Unit
0.5 %
Default value
0
T-SPLY-Y
Adj toner supply amount for all colors
Lv.2 Details
To adjust the offset value of toner supply amount for all colors.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When a symptom that toner supply amount is decreased at an NTD
high latitude occurs
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-3 to 3
Unit
10 %
Default value
0
8
Service Mode > COPIER > ADJUST > DENS
8
Service Mode > COPIER > ADJUST > DENS
COPIER> ADJUST> DENS
T-SPLY-M
Adjustment of M toner supply amount
Lv.2 Details
To adjust the offset value of M toner supply amount.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When E020 occurs frequently
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-3 to 3
Unit
10 %
Default value
0
T-SPLY-C
Adjustment of C toner supply amount
Lv.2 Details
To adjust the offset value of C toner supply amount.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When E020 occurs frequently
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-3 to 3
Unit
10 %
Default value
0
T-SPLY-K
Adjustment of Bk toner supply amount
Lv.2 Details
To adjust the offset value of Bk toner supply amount.
When replacing the DC Controller PCB/clearing RAM data, enter the
value of service label.
Use case
When E020 occurs frequently
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
-3 to 3
Unit
10 %
Default value
0
DMAX-Y
Adj D-max ctrl Y-color dens target VL
Lv.2 Details
An image failure might occur because the density target value of the
D-max control becomes out of the setting table due to environment
change.
Adjust the offset of the yellow density target value of D-max control.
Use case
When any image failure occurs due to environment change
Adj/set/operate method Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
Caution
Do not use this at the normal service.
Display/adj/set range
-8 to 8
Default value
0
Related UI menu
Adjustment/Maintenance> Adjust Image Quality> Auto Adjust
Gradation> Full Adjust, Quick Adjust
8-72
8-72

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents