COPIER> OPTION> NETWORK
SSLSTRNG
Allow weak encryption algorithm for SSL
Lv.2 Details
To set whether to allow using weak encryption algorithm for SSL.
When 1 is set, weak encryption algorithm cannot be used.
Use case
When prohibiting weak encryption algorithm because of security
concern
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Normal mode, 1: Secure mode (Not used TLS_RSA_WITH_
RC4_128_SHA, TLS_RSA_WITH_RC4_128_MD5)
Default value
0
8
Service Mode > COPIER > OPTION > CUSTOM
T-8-49
8
Service Mode > COPIER > OPTION > CUSTOM
■ CUSTOM
COPIER> OPTION> CUSTOM
TEMP-TBL
Fixing control temperature:Plain paper 1
Lv.1 Details
To set the offset of fixing control temperature for plain paper 1 (60 to
75 g/m2).
As the value is incremented by 1, the control temperature is
increased by 5 deg C.
Increase the value when a fixing failure occurs.
Decrease the value when fixing offset occurs.
Use case
When offset/fixing failure occurs on plain paper 1
Adj/set/operate method 1) Enter the setting value (switch negative/positive by -/+ key) and
press OK key.
2) Turn OFF/ON the main power switch.
Caution
Be sure to change the value a little at a time. Otherwise, offset/image
failure occurs when setting an extreme value.
Display/adj/set range
-2 to 2
-2: -10 deg C, -1: -5 deg C, 0: 0 deg C, 1: +5 deg C, 2: +10 deg C
Unit
5 deg C
Default value
0
ABK-TOOL
Allow access from address book mntc tool
Lv.1 Details
To set whether to accept import from the address book maintenance
tool.
Use case
When executing import from the address book maintenance tool
Adj/set/operate method 1) Enter the setting value, and then press OK key.
2) Turn OFF/ON the main power switch.
Display/adj/set range
0 to 1
0: Disabled, 1: Enabled
Default value
0
Supplement/memo
Address book maintenance tool: Tool provided from CMJ.
FAN-ROT
Setting of fan control at condensation
Lv.2 Details
To set fan control when condensation occurs.
When 1 is set, fan control is switched according to the temperature.
Use case
When condensation occurs
Adj/set/operate method Enter the setting value, and then press OK key.
Display/adj/set range
0 to 2
0: Normal, 1: Condensation prevention mode, 2: Not used
Default value
0
DEV-SP1
For R&D
DEV-SP2
For R&D
DEV-SP3
For R&D
DEV-SP4
For R&D
DEV-SP5
For R&D
DEV-SP6
For R&D
DEV-SP7
For R&D
DEV-SP8
For R&D
8-161
8-161