Canon imageRUNNER ADVANCE C350 series Service Manual page 813

Table of Contents

Advertisement

COPIER> DISPLAY> HT-C
SUM-A-C
Dspl ARCDAT screen A C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen A in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-A-K
Dspl ARCDAT screen A Bk-clr ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen A in ARCDAT
control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-B-Y
Dspl ARCDAT screen B Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-B-M
Dspl ARCDAT screen B M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-B-C
Dspl ARCDAT screen B C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen B in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
8
Service Mode > COPIER > DISPLAY > HT-C
8
Service Mode > COPIER > DISPLAY > HT-C
COPIER> DISPLAY> HT-C
SUM-B-K
Dspl ARCDAT screen B Bk-clr ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen B in ARCDAT
control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-Y
Dspl ARCDAT screen C Y-color ctrl differ
Lv.2 Details
To display Y-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-M
Dspl ARCDAT screen C M-color ctrl differ
Lv.2 Details
To display M-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-C
Dspl ARCDAT screen C C-color ctrl differ
Lv.2 Details
To display C-patch control difference of screen C in ARCDAT control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
SUM-C-K
Dspl ARCDAT screen C Bk-clr ctrl differ
Lv.2 Details
To display Bk-patch control difference of screen C in ARCDAT
control.
When hue variation occurs and the displayed value is not in the
tolerable range, execute the auto gradation adjustment (reset target
value). Check the Patch Sensor or replace the developer if not
corrected.
Use case
When hue variation occurs
Adj/set/operate method N/A (Display only)
Display/adj/set range
-1023 to 1023
8-43
8-43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents