Canon imageRUNNER ADVANCE C350 series Service Manual page 964

Table of Contents

Advertisement

■ MISC
COPIER> COUNTER> MISC
T-SPLY-Y
Y toner supply counter
Lv.1 Details
Number of Y-color toner supply blocks.
Counted for every one rotation of Toner Stirring Screw.
Use case
When checking the usage status of toner
Display/adj/set range
0 to 99999999
Unit
1 block
Default value
0
T-SPLY-M
M toner supply counter
Lv.1 Details
Number of M-color toner supply blocks.
Counted for every one rotation of Toner Stirring Screw.
Use case
When checking the usage status of toner
Display/adj/set range
0 to 99999999
Unit
1 block
Default value
0
T-SPLY-C
C toner supply counter
Lv.1 Details
Number of C color toner supply blocks.
Counted for every one rotation of Toner Stirring Screw.
Use case
When checking the usage status of toner
Display/adj/set range
0 to 99999999
Unit
1 block
Default value
0
T-SPLY-K
Bk toner supply counter
Lv.1 Details
Number of Bk color toner supply blocks.
Counted for every one rotation of Toner Stirring Screw.
Use case
When checking the usage status of toner
Display/adj/set range
0 to 99999999
Unit
1 block
Default value
0
ALLPW-ON
For R&D
HDD-ON
Number of HDD start-up times
Lv.1 Details
To count up at HDD start-up.
Use case
When checking the usage status of the product
Display/adj/set range
0 to 99999999
Unit
1 time
ST-NDL
Staple needle counter: Fin-C1
Lv.1 Details
To count the use of the staple needle.
Use case
When checking the usage status of the staple needle.
Display/adj/set range
0 to 99999999
Unit
1 time
8
Service Mode > COPIER > COUNTER > MISC
8
Service Mode > COPIER > COUNTER > MISC
COPIER> COUNTER> MISC
ENT-PTH
Finisher feed path counter
Lv.1 Details
Paper pass counter on the Finisher feed path
Use case
- When checking the number of fed sheets
- When replacing the Finisher
Adj/set/operate method To clear the counter value: Select the item, and then press Clear key.
To change the estimated life: Select the item, enter the value, and
then press OK key.
Caution
- Be sure to clear the counter value when replacing the Finisher.
- Do not clear the counter value when replacing the Buffer Path.
Display/adj/set range
0 to 99999999
Unit
1 sheet
SUC-A-Y
For R&D
SUC-A-M
For R&D
SUC-A-C
For R&D
SUC-A-K
For R&D
8-194
T-8-62
8-194

Hide quick links: